chargeur alimentation extrem
qualite
Masquer

TECSUP Innovation

This product is :
- created by TECSUP.
- conceived by our Design Office.
- made (parameter, assembly and tests) in our workshops at Annecy-Le-Vieux (France, 74).

Every year, TECSUP devotes 12% of its turn over to R&D for the development of ever more reliable solutions, complete and optimized, benefitting from advanced technology, perfectly stabilized and favoring energy economy.

 

  • A complete expertise: energy conversion, storage, control and interfacing, lighting.
  • A multi specialists design office: research, design, industrialization, Interface Man-Machine...
  • A totally mastered and integrated process: conception, prototyping, manufacturing, testing, logistics...
  • Proven technical partners: electronics, mechanics...
  • A flexible organization.

 

Find out more about TECSUP quality.

 

 

Power supply EXTREM 24V/30A

  • 1 DC exit.
  • Entry connection: Europe socket.
    Cable (long 1.5 m ; 1 mm²).
  • Outlet connections: standard terminal.

 

EXTREM

  • Full Power 750w from 96 to 264VAC
  • Power supply version: Stabilised voltage on exit: 24,5 VAC (+/- 1%) independently from mains charge variation
  • Charger version: 3 or 5 stage charge curves; protected from polarity inversions
  • Residual undulation <50mVrms
  • Frequency: 47 to 63Hz.
  • Exit current: <30A
  • Exit connection: wire
  • 16 charge curves (3 or 5 stage) pre-set in the memory
  • Working temperature: Full power from -25°C to +55°C.
  • Storage Temp: -40°C to +70°C
  • Dimensions: 381 x 355 x 122 mm.
  • Weight: 8.5 kg
  • Entry connections: Cable 1.5m long + molded Shuko plug.
  • Exit connections: Cable 2.0m long
  • ON/OFF switch
  • Liaison possible to earth: Screws
  • 3 colored LED visual for charge state.
  • No ventilator, naturally cooled.


Charge Curves (Charger version)

  • Power supply (U =24.5 V +/- 5%).
  • Battery Lithium (U= 29.2 V).
  • Battery sealed Lead 3 stage.
  • Battery spiraled sealed Lead.
  • Battery Open Lead 3 stage.
  • Battery Open Lead 5 stage.
  • Other curves on request.

 

Security

  • Electronic protection against power surges on entry, up to 380VAC (OVP)
  • Electronic protection against short circuits on exit
  • Automatic electronic protection against polarity inversions (on charger version).
  • Complies to MIL STD 461D standards for the following tests:
  • Conducted emission (CE101-4 curve 2)
  • Conducted emission (CE102-1 base curve)
  • Radiated emission (RE 101-2 limit 7cm)
  • Radiated emission (RE 102-2 army curve
  • Conducted susceptibility (CS101)
  • Conducted susceptibility (CS114)
  • Transits (CS 115-1)
  • CEM tests relative to EU markings

 

This site uses audience measurement cookies in order to improve its content.

Do you accept the use of cookies for these purposes?